Correct electrical installationElectrical installations must meet the national regulations and may only be carried out by a qualified electrician.A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regulations.For your own safety, please consult a qualified electrician.Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).Protect the plug connection from moisture.Only connect the unit to a correctly fitted socket.Safe operationif(typeof ez_ad_units!='undefined')ez_ad_units.push([[468,60],'manuals_plus-large-mobile-banner-1','ezslot_1',115,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-1-0');The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace- makers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 0.2 m away from implanteddevices.Keep the socket and power plug dry.Never carry or pull the unit by the electrical cable.Route cables such that they are protected from damage and do not present a tripping hazard.Never carry out technical changes to the unit.Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.Only use original spare parts and accessories for the unit.if(typeof ez_ad_units!='undefined')ez_ad_units.push([[728,90],'manuals_plus-leader-3','ezslot_19',702,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-3-0');Information about these operating instructions
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.Ensure that all work on and with this unit is only carried out in accordance with these instructions. Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_4',116,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_5',116,'0','1']);__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0_1');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_6',116,'0','2']);__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0_2');.large-mobile-banner-2-multi-116border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:2px!important;margin-left:auto!important;margin-right:auto!important;margin-top:2px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!importantWarnings used in these instructionsThe warning information is categorised by signal words, which indicate the extent of the hazard.WA R N I N Gif(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_8',117,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_9',117,'0','1']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0_1');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_10',117,'0','2']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0_2');.leader-2-multi-117border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:2px!important;margin-left:auto!important;margin-right:auto!important;margin-top:2px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!importantIndicates a possibly hazardous situation.Non-observance may lead to death or serious injuries.C A U T I O NIndicates a possibly hazardous situation.Non-observance may lead to slight or minor injuries.N O T EInformation for the purpose of clarification or for preventing possible damage to assets or to the environment.Cross-references used in these instructionsA reference to a figure, e.g. figure A.Reference to another section.Intended useOnly use the product described in this manual as follows:For pumping normal pond water for water features and fountains.Operate in accordance with instructions.The following restrictions apply to the unit:Do not use in swimming ponds.Never use the unit with fluids other than water.Never run the unit without water.Do not use for commercial or industrial purposes.Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.Do not connect to the domestic water supply.Installation and connectionConnecting the hoseHow to proceed:
Pontec PondoMax Eco 2500 Operating Instructions Manual
Eco15001.9 kg25 mmG110 m25002.2 kg25 mmG110 m35003.1 kgG1G110 m50003.4 kgG1G110 m80004.4 kgG1G110 m110004.4 kgG1G110 m140005.4 kgG1G110 m170005.4 kgG1G110 mif(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-medrectangle-1','ezslot_16',101,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-medrectangle-1-0');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-medrectangle-1','ezslot_17',101,'0','1']);__ez_fad_position('div-gpt-ad-manuals_plus-medrectangle-1-0_1');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-medrectangle-1','ezslot_18',101,'0','2']);__ez_fad_position('div-gpt-ad-manuals_plus-medrectangle-1-0_2');.medrectangle-1-multi-101border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:15px!important;margin-left:auto!important;margin-right:auto!important;margin-top:15px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!important
Hi there I have a 7500l pond with about 10 koi and some goldfish. I am running with a Gravity fed Proficlear Premium Drum filter system, a Vitronic 55W UV and pontec pondomax eco 11000 pond pump but the water isnt clearing as good as expected, any suggestions please.
Met de aanschaf van dit product PondoMax Ec 1500/2500/3500/5000/8000/11000/14000/17000 heeft u een goede keuze gemaakt.Lees voor de ingebruikname van het apparaat de gebruiksaanwijzing aandachtig door en maak uzelf volledig vertrouwd met het apparaat.Zorg ervoor dat alle werkzaamheden aan en met dit apparaat alleen worden uitgevoerd in overeenstemming met deze instructies. Houd u aan de veiligheidsinformatie voor een correct en veilig gebruik van het apparaat. Bewaar deze instructies op een veilige plaats! Gelieve de instructies ook te overhandigen bij overdracht van het toestel aan een nieuwe eigenaar.if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_5',116,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0');Waarschuwingen die in deze instructies worden gebruiktDe waarschuwingsinformatie is gecategoriseerd door signaalwoorden, die de omvang van het gevaar aangeven.WAARSCHUWINGif(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_8',117,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_9',117,'0','1']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0_1');if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-leader-2','ezslot_10',117,'0','2']);__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0_2');.leader-2-multi-117border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:2px!important;margin-left:auto!important;margin-right:auto!important;margin-top:2px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!importantGeeft een mogelijk gevaarlijke situatie aan.Niet-naleving kan de dood of ernstig letsel tot gevolg hebben.VOORZICHTIGHEIDGeeft een mogelijk gevaarlijke situatie aan.Niet-naleving kan leiden tot lichte of lichte verwondingen.OPMERKINGInformatie ter verduidelijking of ter voorkoming van mogelijke schade aan activa of aan het milieu.Kruisverwijzingen die in deze instructies worden gebruiktEen verwijzing naar een figuur, bijvoorbeeld figuur A.if(typeof ez_ad_units!='undefined')ez_ad_units.push([[300,250],'manuals_plus-medrectangle-4','ezslot_4',340,'0','0']);__ez_fad_position('div-gpt-ad-manuals_plus-medrectangle-4-0');Verwijzing naar een andere sectie.Beoogd gebruikGebruik het in deze handleiding beschreven product alleen als volgt:Voor het verpompen van normaal vijverwater voor waterpartijen en fonteinen.Werk volgens de instructies.De volgende beperkingen zijn van toepassing op het apparaat:Niet gebruiken in zwemvijvers.Gebruik het apparaat nooit met andere vloeistoffen dan water.Laat het apparaat nooit zonder water draaien.Niet gebruiken voor commerciële of industriële doeleinden.Niet gebruiken in combinatie met chemicaliën, levensmiddelen, licht ontvlambare of explosieve stoffen.Niet aansluiten op de huishoudelijke watervoorziening.Installatie en aansluitingDe slang aansluitenHoe verder te gaan:AKort de getrapte slangadapter eventueel in op de diameter van de gebruikte slang.Dit vermindert drukverliezen.Schroef de getrapte slangadapter op de uitlaat.Schuif de slangklem over de slang, monteer de slang op de slangaansluiting en zet vast met de slangklem.Het apparaat installerenB 2ff7e9595c
Comments